Utility-Scale BESS · HLY-SLS41608Y / 41610Y / 41612Y
LIQUID-COOLING CONTAINER ESS
3,344 kWh  ·  4,180 kWh  ·  5,015 kWh  |  20 ft ISO  |  LiFePO₄ Cobalt-Free  |  Intelligent Liquid Cooling
MEIBESS
meibess.com
Meibess BESS Container Array
COBALT-FREE LFP · EU REG 2023/1542
314 Ah · 3.2 V · IEC 62619 certified
≥ 10,000 CYCLES · 25-YEAR DESIGN LIFE
@ 80% DoD · EOL ≥ 70% SOH · For CATL, GANFENG cells
≥ 94% ROUND-TRIP EFFICIENCY (RTE)
Cell ΔT < 3°C · aux. power −40%
C4/C5 ANTICORROSION · IP54 + IP66
−40°C ~ +60°C · industry-leading range
≥94%
SYSTEM RTE
Round-Trip Efficiency
10,000
CYCLES
80% DoD · EOL ≥70% SOH
5+5yr
WARRANTY
System + Battery
−40/+60
°C RANGE
Operating Temperature
≥99%
AVAILABILITY
Annual System Uptime
Intelligent Liquid Cooling
Closed-loop thermal management maintains cell ΔT < 3°C uniformity across all clusters. Reduces auxiliary power by up to 40% vs. air-cooled. IP66-rated battery modules ensure protection in extreme humidity environments.
3-Level Safety Architecture
Pack-level thermal runaway detection with multi-stage BMS, three-level explosion-proof design, aerosol suppression + water fire protection (optional). <20 ms PCS response for primary frequency regulation.
Plug-and-Play Deployment
Factory-prefabricated 20 ft ISO container — all systems tested before shipment. Energy density >80% higher than air-cooled equivalents — minimises site footprint and commissioning time.
Cloud EMS · Regional Service
AI diagnostic dispatch, OTA upgrades, remote fault diagnostics. Service centres in Europe, Africa, East Asia and Central Asia — spare parts stocked in-region for rapid response without factory lead times.
Grid Peak
Shaving
Solar PV
Integration
Wind Power
Firming
Data Centre
Backup Power
Island &
Microgrid
Frequency
Regulation
EU Regulatory Compliance
Fully compliant with EU Regulation 2023/1542 (EU Battery Regulation). Cobalt-free LFP chemistry satisfies supply chain due diligence and carbon footprint declaration requirements. CE marked for European deployment.
Technical Specifications · System Configuration Data
Parameter HLY-SLS41608Y3,344 kWh Model HLY-SLS41610Y4,180 kWh Model HLY-SLS41612Y5,015 kWh · Flagship
Battery System
Cell ChemistryLiFePO₄ (LFP) — Cobalt-Free · EU Reg 2023/1542
Cell Specification3.2 V / 314 Ah
Battery Configuration332.8 V / 1P104S per rack
No. of Clusters81012 (1P416S)
Rated Energy Capacity3,344 kWh4,180 kWh5,015 kWh
Nominal Voltage1,331 Vdc
DC Voltage Range1,040 V ~ 1,497 V
Max. Charge / Discharge Rate0.5C / 0.5C
Depth of Discharge (DoD)80% DoD (cycle life rated) · 95% max usable capacity
Cycle Life≥ 10,000 cycles @ 80% DoD · EOL ≥ 70% SOH  (For CATL, GANFENG cells)
Round-Trip Efficiency (RTE)≥ 94% (system level)
Design Life25 years
System Warranty5 years system + 5 years battery (5+5)
Thermal Management & Mechanical
Cooling MethodIntelligent Liquid Cooling · Cell ΔT < 3°C
Operating Temperature−40°C ~ +60°C  (industry-leading range)
Storage Temperature−20°C ~ +50°C
Relative Humidity5% ~ 95% (non-condensing)
Max. Operating Altitude4,000 m (derated above 2,000 m)
Noise Level≤ 75 dB(A) at 1 m
Enclosure & Protection
Container Type20 ft Standard ISO · Outdoor Installation · Plug-and-Play
Dimensions (L × W × H)6,058 × 2,438 × 2,896 mm
Weight~ 34 T~ 38.5 T~ 44 T
Container Protection (IP)IP54 (container) · IP66 (battery module)
Anticorrosion GradeC4 standard / C5 optional (coastal & marine)
Safety & Fire Protection
Fire DetectionPack-level thermal runaway · Multi-level BMS
Fire SuppressionAerosol (standard) · Water suppression (optional)
Explosion Protection3-level design · Pressure relief vents
System Availability≥ 99% annual uptime guaranteed
PCS Response Time≤ 20 ms (primary frequency regulation)
Communication & Control
Communication ProtocolModBus TCP · ModBus RTU · CAN · IEC 104 · IEC 61850 (opt.)
Communication InterfaceCAN / RJ45 / RS485
EMS PlatformCloud EMS · AI dispatch · OTA upgrade · Remote O&M
Service & Compliance
Service CentresEurope, Africa, East Asia, Central Asia — spare parts in-region
CertificationsIEC 62619 · IEC 62477 · EU Reg 2023/1542 · CE · UN 38.3 · UN 3536
Single Line Diagram — System Architecture (Reference)
BATTERY CLUSTERS (12 × RACK) RACK 1 1P416S RACK 2 1P416S ··· RACK 12 1P416S MULTI-LEVEL BMS DC BUS 1,040–1,497 Vdc PCS ≤20ms response ModBus / CAN / IEC LV AC 0.4–0.69 kV STEP-UP XFMR LV / MV MV AC 6–35 kV GRID TSO / DSO CLOUD EMS AI Dispatch · OTA · Remote O&M DC Power AC Power Communication (Ethernet / CAN / RS485) *Reference only. Final SLD per project specs.
IEC 62619:2022 IEC 62477-2 IEC 61000-6-2/4 EU Reg 2023/1542 IEC 63056 UN 38.3 UN 3536 CE IEC 60721 C4/C5 ModBus TCP IEC 61850 IEC 104