MB-BESS-261-AC installation
MEIBESS
Battery Energy Storage Systems · meibess.com
Commercial & Industrial BESS · Three Deployment Modes
BESS-Commercial-Industrial-261kWh
261 kWh · LFP · R513A Liquid Cooling · Grid-Forming Standard
All-in-One · DC Battery-Only · Hybrid Inverter Compatible
CE IEC 62619 UL 9540A UL 1973 IP54/IP65 EU Reg 2023/1542 LVRT/HVRT Grid-Forming Std.
261kWh
Energy Capacity
LFP · 314 Ah prismatic
10K+
Cycles @ 80% DoD
EOL ≥70% SOH
≥92%
AC–AC RTE
system level
−30/+55°C
Operating Range
no derating to +35°C
5+5yr
Warranty
system + battery ext.
R513A Liquid CoolingCell ΔT ≤ 2.5°C · GWP 631 eco-refrigerant
Three Deployment ModesAll-in-One · DC-only · Hybrid Inverter
5+5 Year WarrantySystem + battery · pre-priced at order signing
LVRT / HVRT · Grid-FormingCE certified · TN/TT/IT · standard not optional
Battery Parameters
Nominal Capacity261 kWh
Cell ChemistryLFP — Cobalt-Free · EU Reg 2023/1542
Cell Specification3.2 V / 314 Ah prismatic · A-grade · full traceability
DC Voltage Range1,040 – 1,498 V (modes B & C)
Cycle Life10,000 @ 80% DoD · 8,000 @ 95% DoD
0.5C · 25°C · EOL ≥70% SOH
Cycle Life VerificationHenley homologation · 3rd-party NDA
Design Life25 years
Max. DoD100% (95% recommended)
Pack IP RatingIP65 battery module · IP65 PCS
System Parameters
Operating Temp.−30°C to +55°C (no derating to +35°C)
Humidity0–100% RH (non-condensing)
Max. Altitude4,000 m (derate above 2,000 m)
Cabinet IPIP54 standard · IP55 optional
Anti-CorrosionC4 standard · C5 marine optional
Noise Level≤ 75 dB(A) at 1 m
Cabinet Weight≤ 2,800 kg
Dimensions W×D×H1,100 × 1,400 × 2,420 mm
CommunicationModbus TCP · CAN · RS485 · IEC 60870-5-104 · IEC 61850 (opt.) · DNP3
EMSEU Cloud EMS · AI dispatch · OTA · energy-trading ready
Fire SuppressionPack-level Novec · cabinet-level aerosol
CertificationsUL 9540A · UL 1973 · IEC 62619 · EU Reg 2023/1542
Deployment Topologies — Specify at Order
Parameter MODE A — All-in-One · Integrated PCS
…-261kWh-100 / -110 / -125
MODE B — DC Battery-Only · Central PCS
…-261kWh-DC + Central PCS
MODE C — Hybrid Inverter Compatible
…-261kWh-DC + Hybrid Inverter
Power / Configuration 100 / 110 / 125 kW integrated PCS 630–2,500 kW central PCS 30 / 50 / 60 / 100 / 125 kW hybrid inverter
Max. AC Power (1 min) 120 / 132 / 150 kW Per central PCS spec Per inverter model
Mode A — Integrated PCS Specifications (all three sizes)
Rated AC Voltage 400 V, 3L+N+PE · 300–460 V range Not applicable — PCS procured separately for Modes B & C
PCS Efficiency ≥99.0%
AC–AC RTE ≥92% Per selected PCS/inverter
PCS Topology 3-level transformerless · liquid cooled · IP65
Frequency / PF 50/60 Hz · PF −1~+1 · ≥0.99 rated
Max. THDi <3% at rated power
Response Time ≤20 ms PCS capability · <500 ms system Per selected PCS/inverter
DC Connection Parameters (all modes share same battery DC terminals)
Battery DC Voltage 580–1,000 V (PCS input) 1,040–1,498 V (DC bus) Per inverter BESS port spec
Typical Array Size Single cabinet — stack up to 25 units 4–20 cabinets per central PCS 1–3 cabinets per inverter
Common Grid Features — all modes
Grid Features LVRT / HVRT · Grid-forming standard · 4-quadrant reactive power · TN-S · TN-C · TN-C-S · TT · IT networks · CE certified
Best Application C&I sites, EV buffers, demand-charge, solar self-use EPC multi-cabinet MWh projects, freq. regulation Solar+storage, off-grid, microgrid, PV retrofit
BESS-Commercial-Industrial-261kWh  ·  261 kWh Liquid-Cooled C&I BESS  ·  Mode A / B / C
Application Scenarios
Peak cut Cap BESS active
Peak Shaving
Cut demand charges by shifting load from peak to off-peak tariff windows
HLY-BESS Daytime surplus → stored → evening
Solar Self-Use
Store daytime PV surplus for evening discharge — maximise renewable ROI
Grid OUTAGE STS ≤ 20 ms switchover
Backup Power
Automatic <20 ms switchover protects critical loads from grid outages
Hz Time → 50 Hz nominal BESS response VPP / FCR
Frequency Reg.
Fast-response ancillary services for grid operators and VPP aggregators
Grid 400V HLY-BESS DC Fast No grid upgrade needed
EV Charging
Buffer peak demand for high-power EV hubs without grid upgrade costs
PV Array Wind HLY-BESS Critical load General load Island Mode Ready
Off-Grid / Microgrid
Full island-mode with automatic grid reconnection for microgrids
System Architecture — Single Line Diagram
PV BESS GRID PV Array DC PV Inverter PV Meter Battery 261 kWh LFP DC PCS 100/110/125kW BESS Meter Bidirectional AC BUS 400V 3ph Multifunction Meter LOAD Grid Distribution Transformer Grid Meter POC EMS Energy Mgmt System Cloud Monitor 24/7 · OTA · AI DSO / VPP Grid Operator AC Line DC Line Communication
Warranty & Service
5 YR
Product Warranty
Full system parts & labour · 48h European response · On-site technicians
+5 YR
Battery Warranty
Cell capacity guarantee · Tier-1 cell manufacturers · Pro-rated replacement
25 YR
Design Life
Dual cycle-life verified · Thermal management optimised · OTA upgradeable
24/7
Cloud Monitoring
Remote diagnostics & OTA · AI predictive maintenance · Real-time alarms
Ordering Information
Model NumbersA: BESS-Commercial-Industrial-261kWh-100 · -110 · -125
B/C: BESS-Commercial-Industrial-261kWh-DC (+ central PCS or hybrid inverter)
Hybrid InverterInverter-Hybrid 30 / 50 / 60 / 100 / 125 kW (Mode C)
Central PCSCentral PCS 630–2,500 kW (Mode B)
Cabinet ColourRAL 7035 Light Grey standard · custom RAL on request
Warranty5+5 Year Warranty (pre-priced at order signing)
Anti-CorrosionC4 standard · C5 marine-grade on request
Grid ComplianceCE · LVRT/HVRT · TN/TT/IT · country codes per project
EMSEU Cloud EMS — energy-trading ready
Lead Time35 days ex-works from contract + deposit
MOQ1 unit · project pricing from 3 units
Get in touch
Request a Quote or
CAPEX / ROI Analysis
sales@meibess.com
meibess.com
WhatsApp: +86 158 2241 5114
Meibess · Jinan, Shandong Province, China
Tell us your site power (kW), PV capacity (if any), and target discharge hours — we'll recommend the right mode.
All specifications subject to change without prior notice. Values represent nominal performance at 25°C unless stated otherwise. Cycle life tested per Henley homologation protocol; independent third-party test reports available under NDA on request. AC–AC round-trip efficiency is system-level. Modes B and C require separate PCS or hybrid inverter procurement — consult Meibess for project-specific configuration and compatible equipment selection. © 2026 Meibess. All rights reserved.